Home –Static LV Power Factor Corrector
PMI Static Low Voltage Power Factor Correction systems deliver fast, precise, and bidirectional reactive power compensation for industrial applications. Based on thyristor-controlled technology, they dynamically compensate both inductive and capacitive loads, responding rapidly to load variations. This ensures improved power quality, reduced system losses, and continuous compliance with utility and grid requirements.
| INPUT & CONTROL | |
|---|---|
| Model | EKM |
| 1 Phase Power Options | 22,5 / 45 / 90 / 135 / 180 / 270 / 360 Kvar/440VAC |
| Working Technique | Thyristor/Diode Zero Current Switching |
| Correction Tecnique | Each Phase Independent Measurement (1Phase) / Each Phase Measurement (3Phase) |
| Controlling | dsPIC Microcontroller |
| Efficiency | >90% |
| Isolation Voltage | 2.500 VAC (Between Input-Output, Input-Case, Output-Case) |
| Correction Tolerance | ±%2 VAR |
| Capacitive Step Number | 32 / 64 (for 22,5 KVAr 32 Steps, for more than 22,5KVAr 64 Steps) |
| INPUT | |
|---|---|
| Nominal Input Voltage | 380/400 VAC (3 Phase) |
| Input Voltage Tolerance | ±20% |
| Nominal Input Frequency | 50 – 60 Hz (Optional) |
| Input Frequency Tolerance | ±5% |
| Power Factor | >0.8 |
| Input Protection | Thermal-Magnetic Overcurrent, Overvoltage ve EMI-RFI Filter |
| Momentary Voltage and Impact Protection | IEEE 587 (4500 A, 110 Joules) |
| DIGITAL FRONT PANEL | |
|---|---|
| Indicator ve Buttons | 2 x 16 LCD Panel, Menu Choosing and Parameter Adjust Buttons |
| Warning Messages | Input Voltages Normal/Overvoltage/Undervoltage,Input Fuse Open/Close,Overtemperature,Temperature Normal,Insufficient Correction,Over THD,Correction Normal,Communication Failure/Normal,Device Failure/Normal,Self Test Start/End |
| Monitorring Parameters | Cos Fi L1/L2/L3, PF L1/L2/L3/Total, Input Voltages L1/L2/L3, Apperant Power (VA) L1/L2/L3/Total, Active Power(W) L1/L2/L3/Total, Reaktive Power (VAR) L1/L2/L3/Total |
| Adjustable Parameters | Capacitive / Inductive Side Working,Date/Time ,Alarm Volume Level,Communication Address,LV/HV Operate |
| Voiced Alarm | During Indication Messages in 2 seconds 2 short “Bip” |
| Communication | Monitorring and Adjusting Parameters over Computer via RS-232 ve RS-485, 256 Event Logs, GSM communication (Option), TCP/IP |
| ENVIRONMENT | |
|---|---|
| Cooling | AC Fan (Standard) / Natural Cooling (Option) |
| Elektrically Noise Reducing | FCC Part 15 Class B |
| Cabin Protection Level | IP20 / RAL7035 as standard, (Higher IP rating and different colors are available, please consult) |
| Nominal Temperature | -10 / +40 °C (Higher operating temperatures are available, please consult ) |
| Relative Humidity | 0 – 90%. Higher relative humidity are available, please consult |
| Working Height | Maximum 1.000 Mt (Higher altitudes requires de-rating, please consult ) |
| Noise Level | Max. 60dB in 1 Meter Dıstance |
| Electrical Standarts | EN 50091-1 (Safety) / EN 50091-2 (EMC) |
| INPUT & CONTROL | |
|---|---|
| Model | EKT |
| 1 Phase Power Options | 75 / 150 / 230 / 310 / 460 / 620 kVA/440VAC |
| Working Technique | Thyristor/Diode Zero Current Switching |
| Correction Tecnique | Each Phase Independent Measurement (1Phase) / Each Phase Measurement (3Phase) |
| Controlling | dsPIC Microcontroller |
| Efficiency | >%90 |
| Isolation Voltage | 2.500 VAC (Between Input-Output, Input-Case, Output-Case) |
| Correction Tolerance | ±%2 VAR |
| Capacitive Step Number | 32 / 64 (for 75 KVAr 32 Steps, for more than 75 KVAr 64 Steps) |
| INPUT | |
|---|---|
| Nominal Input Voltage | 380/400 VAC (3 Phase) |
| Input Voltage Tolerance | ±20% |
| Nominal Input Frequency | 50 – 60 Hz (Optional) |
| Input Frequency Tolerance | ±5% |
| Power Factor | >0.8 |
| Input Protection | Thermal-Magnetic Overcurrent, Overvoltage ve EMI-RFI Filter |
| Momentary Voltage and Impact Protection | IEEE 587 (4500 A, 110 Joules) |
| DIGITAL FRONT PANEL | |
|---|---|
| Indicator ve Buttons | 2 x 16 LCD Panel, Menu Choosing and Parameter Adjust Buttons |
| Warning Messages | Input Voltages Normal/Overvoltage/Undervoltage,Input Fuse Open/Close,Overtemperature,Temperature Normal,Insufficient Correction,Over THD,Correction Normal,Communication Failure/Normal,Device Failure/Normal,Self Test Start/End |
| Monitorring Parameters | Cos Fi L1/L2/L3, PF L1/L2/L3/Total, Input Voltages L1/L2/L3, Apperant Power (VA) L1/L2/L3/Total, Active Power(W) L1/L2/L3/Total, Reaktive Power (VAR) L1/L2/L3/Total |
| Adjustable Parameters | Capacitive / Inductive Side Working,Date/Time ,Alarm Volume Level,Communication Address,LV/HV Operate |
| Voiced Alarm | During Indication Messages in 2 seconds 2 short “Bip” |
| Communication | Monitorring and Adjusting Parameters over Computer via RS-232 ve RS-485, 256 Event Logs, GSM communication (Option), TCP/IP |
| ENVIRONMENT | |
|---|---|
| Cooling | AC Fan (Standard) / Natural Cooling (Option) |
| Elektrically Noise Reducing | FCC Part 15 Class B |
| Cabin Protection Level | IP20 / RAL7035 as standard, (Higher IP rating and different colors are available, please consult) |
| Nominal Temperature | -10 / +40 °C (Higher operating temperatures are available, please consult ) |
| Relative Humidity | 0 – 90%. Higher relative humidity are available, please consult |
| Working Height | Maximum 1.000 Mt (Higher altitudes requires de-rating, please consult ) |
| Noise Level | Max. 60dB in 1 Meter Dıstance |
| Electrical Standarts | EN 50091-1 (Safety) / EN 50091-2 (EMC) |
From design to commissioning, we deliver dependable power electronics for critical systems worldwide.
PMI designs and manufactures reliable power electronics solutions for critical industrial applications, delivering quality, safety, and long-term performance worldwide.